SCAN 61 Manuale del Proprietario

Navigare online o scaricare Manuale del Proprietario per Stufa a legno SCAN 61. SCAN 61 Owner`s manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
SCAN 60 and 61
INSTRUCTIONS FOR
INSTALLATION AND USE
Tested &
Listed by
Beaverton
O regon U SA
OMNI-Test Laboratories, In c.
Save these instructions
February 2004
KROG IVERSEN & CO. A/S - 5492 VISSENBJERG - DENMARK
Vedere la pagina 0
1 2 3 4 5 6 ... 26 27

Sommario

Pagina 1 - SCAN 60 and 61

SCAN 60 and 61 INSTRUCTIONS FOR INSTALLATION AND USE Tested &Listed byBeavertonO regon U SAOMNI-Test Laboratories, In c. Save th

Pagina 2 - Table of Contents:

10 Alcove Installation Requirements: Whenever the stove is placed in a location where the ceiling height is less than 7’ tall, it is considered

Pagina 3 - 1. INTRODUCTION

11 Mobile Home Installation: US only In addition to standard installation the following requirements are mandatory for installation in a mobile

Pagina 4

12 Outside air requirements Required for mobile home and in certain localities (Check with building officials) Outside air must not be drawn fr

Pagina 5 - 2. INSTALLATION

13 Chimney Installation: Do not connect this unit to a chimney flue serving another appliance. Do not connect to any air distribution duct or s

Pagina 6 - The Floor

14 Chimney Connection The chimney connector is ether a single or double walled pipe, depending on the type of installation, used to connect the s

Pagina 7 - Ceiling Height

15 Rear Vent Installation For venting into a masonry or a back standing steel chimney through the top vent the top horizontal portion of a single

Pagina 8

16 Combustible Wall Chimney Connector Pass-Throughs. Method A. 12” (304.8 mm) Clearance to Combustib

Pagina 9

17 NOTES: 1. Connectors to a masonry chimney, excepting method B, shall extend in one continuous section through the wall pass-through system an

Pagina 10

18 3. INSTRUCTIONS FOR USE Ash Drawer The ash drawer located behind the fuel door is designed to make cleaning easier by containing the ashes in

Pagina 11

19 Ceramic Packing Cord These stoves are equipped with a ceramic packing cord to ensure the tightness of the doors and the glasses. This packing

Pagina 12

2 Table of Contents: 1. INTRODUCTION...

Pagina 13

20 4. OPERATION WARNING: DO NOT USE GASOLINE, LIGHTER FLUID, KEROSENE OTHER FLAMMABLE LIQUIDS TO START OR FRESHEN A FIRE IN THE STOVE KEEP ALL

Pagina 14 - Chimney Connection

21 5. MAINTENANCE Ash Disposal and Removal CAUTION: Be sure the fire is out and the stove is cold before removing ashes! Be careful when you e

Pagina 15

22 Removing Baffle for Cleaning. Be sure the fire is out and the stove is cold before removing baffle plate. Be cautions with handling the plat

Pagina 16

23 Slide the air tube collar (pos.2) to the left, swing the air tube (pos.1) down and remove it. Replacement Part List SCAN 60 and

Pagina 17 - Chimney height requirements:

24 Door Glass A commercial glass cleaner designed for stoves is recommended for cleaning the glass. The glass can also be cleaned as follows: Dip

Pagina 18 - 3. INSTRUCTIONS FOR USE

25 6. TROUBLESHOOTING Smoke: - Insufficient chimney draught! - Check if the chimney has the right dimension. - Check if the smoke pipe or chimne

Pagina 19

26 7. WARRANTY CONDITIONS FOR SCAN WOOD BURNING PRODUCTS All SCAN wood stoves; inserts and fireplaces are subject to a strict quality control, b

Pagina 20 - 4. OPERATION

27 8. EPA Sticker

Pagina 21 - 5. MAINTENANCE

3 We welcome you as a new owner of a SCAN wood-burning stove. In purchasing a SCAN stove you have joined the growing ranks of concerned individua

Pagina 22

4 SAFETY PRECAUTIONS USE A METAL CONTAINER WITH A TIGHT FITTING LID TO DISPOSE OF ASHES. NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSE

Pagina 23

5 2. INSTALLATION Precaution If your SCAN stove is not properly installed, operated and maintained, a house fire may result. For your safety, f

Pagina 24 - Dimensions SCAN 60 and 61

6 NOTE: The clearances expressed in inches are those approved for installation in the United States. The clearances in expressed in millimeters a

Pagina 25 - 6. TROUBLESHOOTING

7 Corner installation Floor pad at Corner Installation Model Floor protection A B C D Scan 60 USA 16” 7,5” 73,8” 104,5”Scan 60 Canada

Pagina 26

8 Combustible Wall Clearance for Top Vent Installation If the stove is to be placed at side and back walls of combustible materials the followin

Pagina 27 - 8. EPA Sticker

9 Combustible Wall Clearance for Rear Vent Installation If the stove is to be placed at side and back walls of combustible materials the followi

Commenti su questo manuale